The gateway has no power

If the gateway does not power on, or loses power unexpectedly, a blown fuse is a common cause.

Always disconnect the battery before replacing any fuse.

The gateway uses ATO-type fuses:

Fuse Type Voltage Current Location
Battery fuse ATO 32 V 10 A Battery enclosure
PCB fuse ATO 32 V 10 A Gateway enclosure
Gateway fuse ATO 32 V 3 A Gateway enclosure

Replace a blown fuse with a new one of the same rating.

Replace the battery-enclosure fuse

  1. Disconnect the battery.
  2. Release the lock tab and pull the bottom of the fuse holder down to open the case.
  3. Pull out the fuse and insert a new one of the same rating.
  4. Click the fuse case back together.

Replace a gateway-enclosure fuse

  1. Disconnect the battery.
  2. Open the gateway enclosure with a Phillips screwdriver.
  3. Pull the fuse straight out and push a new one of the same rating into its place.
  4. Close the enclosure.

Reconnect the battery when you are done. If the new fuse also blows, stop and contact SenArch — repeated blown fuses point to a fault that needs investigation.